Skip to content
Pay invoice Customer portal Book maintenance Free site survey

Emergency Lighting Installation, Testing and Maintenance for Commercial and Residential Buildings

Bell Fire & Security installs, tests, and maintains emergency lighting systems for commercial premises, residential blocks, care facilities, schools, and industrial buildings across Scotland. Our SELECT-accredited electricians provide emergency lighting installation, monthly and annual testing, maintenance, and system upgrades in line with BS 5266 and Scottish fire safety duties under the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006.

  • SELECT-Accredited Electricians  — Emergency lighting installations carried out by accredited engineers to BS 5266
  • Annual Testing and Certification  — Three-hour discharge tests and full system inspections with certificates issued following completion
  • New Installations and Upgrades  — Self-contained and central battery systems, maintained and non-maintained luminaires, and LED upgrades
  • Monthly and Annual Testing Programmes  — Planned testing schedules with written records for your compliance file
Green illuminated emergency exit sign with running man symbol and right arrow, mounted beneath exposed ceiling services in a dark commercial interior.
 

Emergency Lighting Services for Every Building Type

Emergency lighting is the system that keeps escape routes visible when the mains power fails. In a building evacuation, the difference between a lit corridor and a dark one is not marginal — it is the difference between an orderly exit and a dangerous one. Most building owners and facilities managers know they have emergency lighting. Far fewer are confident that it has been tested in the last twelve months, that the records are up to date, or that every luminaire is operational.

For Business Owners and Commercial Operators

Scottish fire safety law requires dutyholders to make sure escape routes are safe and adequately illuminated in the event of power failure or fire. Emergency lighting is a key part of meeting that duty. If a fire risk assessment identifies missing, inadequate, or untested emergency lighting, action should be taken to restore the system to a compliant standard.

Bell installs and maintains emergency lighting systems for offices, retail premises, warehouses, hotels, and commercial buildings across Scotland. We carry out annual three-hour discharge tests, provide written records, and can include emergency lighting maintenance within a planned service programme so no test date is missed.

For Facilities Managers

Emergency lighting testing is not a single annual event — it requires monthly functional tests as well as the annual full-duration test. The monthly test is typically carried out by the responsible person in-house, but the annual test must be carried out by a competent person and documented. Managing test records across a portfolio of buildings, ensuring every system has a current annual test certificate, and responding when a luminaire fails its test requires a systematic approach.

Bell’s planned maintenance contracts cover the annual test and certification for all your buildings on a fixed schedule, with written records issued after every visit. We track test dates across your portfolio and provide consolidated reporting suitable for your compliance team and insurer.

For Landlords & Property Managers

In multi-occupied residential buildings, the responsible person is required to maintain emergency lighting in communal escape routes — corridors, stairwells, and lobbies — as part of the fire safety obligations that apply to the building. This applies whether the building is a purpose-built apartment block, an HMO, or a converted property with multiple tenancies.

Bell provides installation and annual testing services for residential landlords, with documentation in the format required for fire safety files, licensing applications, and regulatory inspections. For HMO landlords, an emergency lighting certificate is typically a requirement of the licence.

What Is Emergency Lighting and How Does It Work?

Emergency lighting is a system of luminaires and exit signs that activates automatically when the mains electrical supply to the normal lighting circuit fails — illuminating escape routes, highlighting exit signs, and enabling safe evacuation in conditions of darkness or reduced visibility.

Normal Operation

Standard mains-powered lighting operates as normal. Emergency luminaires remain on standby, continuously charging their battery backup from the mains supply they are connected to.

Mains failure

Emergency Activation

On mains failure, each emergency luminaire switches instantly to its own battery backup — maintaining illumination on escape routes for the required duration, independent of any external power supply.

Maintained vs Non-Maintained Emergency Lighting

Whether a luminaire is lit continuously or only on mains failure is one of the most commonly misunderstood aspects of the specification.

TypeOperationTypical Locations
Non-maintainedOff during normal operation. Activates automatically when mains supply fails — providing emergency illumination only during a power failure or test.Offices, retail, and educational buildings occupied during daytime hours, where the risk of evacuation in darkness is primarily during a power failure.
MaintainedLit at all times — both during normal mains-powered operation and on mains failure. Battery backup maintains illumination when mains power is lost.Cinemas, theatres, nightclubs, hotel bedrooms, stairwells used in hours of darkness, and any location occupied in conditions of reduced visibility.
CombinedSeparate circuits for normal and emergency lighting within the same fitting. Normal circuit energised during operation; emergency circuit activates on mains failure.Buildings requiring flexibility where a single luminaire must serve both the normal and emergency lighting function.
SustainedUses the same lamp for both normal and emergency operation. One lamp circuit connects to mains; the other to the battery. Battery circuit maintains the lamp on failure.Similar to maintained luminaires — where a single fitting must serve both functions with a single lamp.

Self-Contained vs Central Battery Systems

Emergency lighting can be powered by individual batteries within each luminaire, or by a central battery system feeding multiple luminaires from a single source.

Self-Contained

Each luminaire contains its own battery and charging circuit, charging from the mains circuit it is connected to.

Advantages
  • Simpler installation — no additional wiring beyond the normal circuit
  • More resilient — failure of one luminaire does not affect others
Limitations
  • Individual battery failures must be identified through testing
  • Batteries require replacement in each luminaire individually
Typical use Most common in commercial buildings, residential blocks, and smaller premises

Central Battery System

A central battery unit powers multiple luminaires through dedicated emergency circuit wiring, maintaining all connected luminaires on mains failure.

Advantages
  • Easier monitoring — battery status for all luminaires visible at a single point
  • Longer battery life in some configurations
Limitations
  • More complex installation requiring dedicated circuit wiring
  • Central unit failure can affect multiple luminaires simultaneously
Typical use Larger premises, hospitals, and buildings where centralised monitoring and longer battery duration are required

Emergency Lighting Duration

BS 5266-1 requires emergency lighting luminaires to operate for a minimum of one hour on battery backup in most building categories. Sleeping risk premises require a minimum of three hours.

Building CategoryMinimum DurationNotes
Offices, retail & commercial premises1 hour3-hour systems are common in practice — they provide more headroom and simplify procurement by using the same systems as sleeping risk premises.
Hotels, care homes & hospitals3 hoursSleeping risk buildings where extended evacuation time may be required and occupants may not be fully awake or alert.
Residential apartment blocks3 hoursCommunal escape routes in multi-occupied residential buildings.
Schools & educational premises1 hourOccupied during daytime — 1-hour duration is typically sufficient for evacuation and the immediate post-evacuation period.
Industrial & warehouse premises1 hourHigher-risk environments may benefit from 3-hour systems depending on risk assessment findings.

How Our Emergency Lighting Installation Works

Emergency lighting installation is a regulated electrical installation that must be designed, installed, and commissioned in compliance with BS 5266-1. The luminaire positions, spacing, and illumination levels must meet the lux requirements of the standard at floor level on escape routes. Here is how Bell manages the full process.

1

Free Site Survey

A SELECT-accredited engineer visits your building to assess the escape routes, stairwells, exit sign positions, and areas requiring emergency lighting. We review the building layout against the BS 5266-1 positioning requirements and confirm the luminaire types, spacing, and system configuration appropriate for the building category. No charge and no obligation.

2

System Design and Fixed-Price Quote

We produce a luminaire schedule and layout drawing showing the proposed positions, types, and wiring arrangement for the system. The design is checked against BS 5266-1 to confirm that minimum lux levels will be achieved at floor level on all escape routes. You receive a fixed-price quote covering all luminaires, wiring, containment, and commissioning.

3

Professional Installation

Our SELECT-accredited electricians install the system in accordance with the design, BS 5266-1, and the requirements of BS 7671 (the IET Wiring Regulations). All wiring is installed in appropriate containment, luminaires are positioned and fixed correctly, and test facilities are provided. For systems in occupied buildings, installation is coordinated to minimise disruption.

4

Commissioning and Testing

The completed system is commissioned and tested. Every luminaire is activated and checked for correct operation. The system is subjected to a full discharge test to confirm the battery duration meets the required minimum. All exit signs are confirmed visible and correctly positioned.

5

Documentation and Handover

A commissioning certificate is issued confirming the system meets BS 5266-1. A log book is provided for the building, recording the installation details, the luminaire schedule, and the test records. We confirm the monthly and annual testing requirements with the responsible person and set up the planned maintenance schedule.

Emergency Lighting System

The performance of an emergency lighting system is determined by its design, the quality of the luminaires, and the rigour of the testing and maintenance programme. Here are the features that define a properly specified and installed system.

Automatic Mains Failure Activation

Every emergency luminaire activates automatically and without delay when the mains supply fails. There is no manual intervention required, and the system does not rely on any occupant being present to switch it on.

Minimum 1-Lux Illumination on Escape Routes

BS 5266-1 requires suitable illumination along escape routes, including a minimum average illumination of 1 lux along the centre line. Bell’s emergency lighting designs are checked against these requirements at design stage, not assumed to be met by luminaire positions alone.

LED Luminaires

Bell installs LED emergency luminaires as standard. LED emergency lighting provides better energy efficiency during maintained operation, longer lamp life, and improved illumination consistency during the discharge period compared with older fluorescent alternatives.

Three-Hour Battery Capability

Bell specifies three-hour battery duration as a default where the building category permits. Three-hour systems provide more operational headroom than one-hour systems and are commonly required for sleeping risk premises and higher-risk environments.

Test Facilities

Every luminaire includes a test facility, such as a press-to-test button or key-operated test switch. This allows the dutyholder to carry out monthly functional testing without turning off the normal lighting circuit in an occupied building.

Exit Sign Compliance

Exit signs are installed to the illuminated or photoluminescent standard required by the fire strategy and BS 5266-1. Signs are positioned at escape route changes, junctions, final exits, and key decision points using BS ISO 7010 running figure pictograms.

Full BS 5266-1 Documentation

Every Bell emergency lighting installation is accompanied by commissioning documentation, a luminaire schedule, and a log book. The log book is used to record ongoing functional tests, annual discharge tests, defects, repairs, and maintenance history for the system.

Why Choose Bell for Your Emergency Lighting?

SELECT-Accredited Electricians

Emergency lighting installation is electrical work and should be carried out by a competent person. Bell’s SELECT-accredited electricians install and commission emergency lighting systems across Scotland in line with BS 5266-1 and BS 7671.

This helps ensure the system is properly designed, safely installed, and supported by appropriate electrical competency and documentation.

BS 5266-1 Compliant Design and Installation

BS 5266-1 is the British Standard for emergency lighting. It covers design requirements such as luminaire spacing, minimum illumination levels, positioning at changes in direction, exit points, stairways, and key safety locations.

Bell designs, installs, tests, and maintains emergency lighting systems in line with BS 5266-1, with certification and records referencing the relevant standard.

Same-Day Certificates

Annual test certificates are issued following completion of the test visit, helping facilities managers, dutyholders, and managing agents keep compliance files up to date without unnecessary delay.

The engineer updates the emergency lighting log book and provides the relevant test documentation so records are available for audits, reviews, and fire safety files.

Full Log Book Maintenance

Every visit Bell makes to an emergency lighting system — monthly test, annual discharge test, or fault response — is recorded in the system log book.

The log book is the primary compliance record for the system. Keeping it current helps demonstrate that testing, defects, repairs, and maintenance have been properly managed.

Trusted Since 1919

Bell Fire & Security has been protecting buildings in Scotland for over 100 years. For a safety system whose purpose is most critical in the moments when everything else has gone wrong, working with a contractor who has been providing reliable service for generations matters. More than 60% of our work comes from repeat customers.

Posted on Google Google
Julie Dickson
50 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Very efficient, good service. Polite and friendly. Thank you.
Posted on Google Google
Helen K
125 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Annual maintenance carried out by David, up to usual high standard of efficiency and communication. Been with Bell Alarms for 30 years and service never disappoints, would thoroughly recommend!
Posted on Google Google
Lynette McSwan
132 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
David and Callum arrived at the exact booking time for the alarm service.Both gents very efficient,pleasant and conducted a thorough service on the alarm.Great service from Bell Alarms.

Owner's reply
Thank you, Lynette, for your wonderful 5-star review. We're delighted to hear that David and Callum arrived on time and provided the efficient, professional service that we pride ourselves on. It's great to know that they carried out a thorough inspection of your alarm system while ensuring the visit was a pleasant experience from start to finish. We'll be sure to pass your kind comments on to both David and Callum, who will be delighted to receive your feedback. Thank you for choosing Bell Fire & Security. We truly appreciate your support and look forward to assisting you again in the future.
Posted on Google Google
Stephen Davidson
134 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Thanks to David for the service check on my alarm system. Friendly professional service, system now fully updated and functioning as it should. I’ve been with Bell Fire and Security Ltd from the start and I’m more than happy to recommend them based on my experience to date.

Owner's reply
Thank you, Stephen, for your fantastic 5-star review and for your continued loyalty to Bell Fire & Security over the years. We're delighted to hear that David provided a friendly and professional service and was able to ensure your alarm system was fully updated and operating exactly as it should. We take great pride in delivering reliable service and expert support, so it's wonderful to know that this was reflected in your experience. Your support and recommendation mean a great deal to the entire team. Thank you for placing your trust in us from the very beginning. We look forward to continuing to support your fire and security needs for many years to come.
Posted on Google Google
Alan Leckerman
135 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Gary was very helpful, and efficient when servicing our alarm

Owner's reply
Thank you for your lovely review, Alan. We’re pleased to hear Gary was helpful and efficient while servicing your alarm! We’ll be sure to pass your kind feedback on to him. 😁 - Bell Fire & Security Team
Posted on Google Google
francis patton
136 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Great service as always from a very reliable company. I’ve been with Bell for 18 years now and never had any issues, not many companies can beat that. Gary was today’s engineer and he couldn’t have been better, friendly, knowledgeable and polite, excellent all round.

Owner's reply
Thank you, Francis, for your wonderful review and for trusting us at Bell for the past 18 years! We truly appreciate your loyalty and kind words about our reliability and service. It’s great to hear Gary made such a positive impression with his friendly, knowledgeable and polite approach. We’ll be sure to pass your feedback on to him. Thanks again, from The Bell Fire & Security Team :)
Posted on Google Google
Fiona Shanks
147 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Gary, was friendly and efficient.

Owner's reply
Thank you, Fiona, for taking the time to leave us a review. We’re really pleased to hear Gary was friendly and efficient — we’ll be sure to pass your kind feedback on to him. 😊 From the Bell Fire & Security Team
Posted on Google Google
Graeme Mcmaster
149 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Fast response very good in private areas
Posted on Google Google
Annette Shannon
161 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Great company to deal with. Nothing is too much trouble and Alan was great with my alarm maintenance while the salon was so busy

Owner's reply
Thank you, Annette, for your lovely review. We’re so pleased to hear you had a great experience with us, especially while the salon was busy. Alan will be delighted to know his help with your alarm maintenance was appreciated. 😊 Bell Fire & Security Team
Posted on Google Google
Rena Dunsmore
163 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Gary arrived early which was great for us. He was pleasant efficient and professional.

Owner's reply
Thank you, Rena, for taking the time to leave us a 5-star review. It’s great to hear Gary’s early arrival worked well for you and that he provided a pleasant, efficient, and professional service. We’ll gladly share your kind words with him. 😁 Bell Fire & Security Team

Emergency Lighting Testing and Maintenance

An emergency lighting luminaire with a failed battery will not illuminate anything during a power failure. A failed battery provides no visible indication during normal operation. The only way to confirm an emergency luminaire is operational is to test it. This is why BS 5266-1 mandates both monthly functional tests and annual full-duration tests — and why both must be recorded.

Monthly Functional Test

The monthly functional test simulates a mains failure by activating the emergency circuit for a short period, typically two to three minutes, and confirming that every luminaire operates.

The test is usually carried out by the dutyholder or a designated in-house staff member using the test facilities fitted to each luminaire. Every monthly test result should be recorded in the emergency lighting log book.

Bell provides guidance on how to carry out the monthly test correctly, what to record, and what to do if a luminaire fails. For buildings without a staff member able to carry out monthly checks, Bell can include monthly testing visits in a planned maintenance contract.

Annual Full-Duration Discharge Test

The annual test is a full discharge of the battery. The luminaires are activated in emergency mode and left running for the full rated duration, usually one or three hours depending on the system.

Every luminaire must remain operational throughout the test period for the system to pass. The test confirms that batteries have not degraded below the rated capacity and that each luminaire can sustain illumination for the required duration during a real power failure.

The annual test should be carried out by a competent person. Bell’s engineers carry out the test, check every luminaire during and after the discharge, record any failures, and issue a certificate on completion. Failed luminaires are identified, with battery replacement, luminaire replacement, or further remediation carried out or scheduled.

Fault Response and Battery Replacement

When a luminaire fails — either during a test or due to physical damage — Bell provides call-out replacement for failed luminaires and batteries. Most self-contained emergency luminaires use sealed lead-acid or nickel-cadmium batteries with a typical service life of three to four years. Bell tracks the installation date and battery type for systems we maintain and advises on battery replacement before the end of the expected service life, reducing the risk of test failures.

Bell engineer carrying out electrical works on a sounder bell.

Testing Responsibilities Summary

Test TypeFrequencyWho Carries It OutWhat Is Recorded
Functional testMonthlyDutyholder, designated staff member, or Bell under a planned contractDate, duration, luminaires tested, and any failures, entered in the log book
Full-duration testAnnuallyCompetent person, such as Bell’s SELECT-accredited engineersDate, test duration, pass/fail result for each luminaire, certificate issued, and log book updated
Visual inspectionMonthly, combined with functional testDutyholder or designated staff memberPhysical condition of each luminaire, including damage, obstruction, or missing fittings
Battery replacementAs required, typically every 3–4 years depending on battery type and conditionCompetent personReplacement date, battery specification, and any related remedial work

What the Annual Inspection Covers

Bell’s annual emergency lighting inspection includes the full-duration discharge test, visual inspection of every luminaire for physical damage, correct positioning, and unobstructed light output, confirmation that exit signs are correctly positioned and legible, and checks of wiring condition where accessible.

The inspection also includes a review of the log book to confirm monthly tests have been carried out and recorded since the last annual visit. The inspection report is issued on completion and the log book is updated.

Protect Your Property — Book a Free Site Survey

NSI Gold Accredited Free Site Survey No Obligation

How Much Does Emergency Lighting Installation and Maintenance Cost?

Emergency lighting costs depend on the number of luminaires required, the building layout, the system type (self-contained or central battery), whether the installation is new build or retrofit, and the access conditions. Annual testing costs depend on the luminaire count and building size. Here are the main factors.

Number of Luminaires

BS 5266-1 positioning requirements determine how many luminaires are needed, typically at changes of direction, exits, stairways, key safety points, and at sufficient spacing to achieve the required illumination level on escape routes.

System Type

Self-contained luminaires are usually less expensive to install than central battery systems because they do not require additional dedicated circuit wiring to a central unit. Central battery systems may be required for larger premises or where centralised monitoring is specified.

Maintained vs Non-Maintained

Maintained luminaires remain lit during normal operation, while non-maintained luminaires only activate when the mains supply fails. LED maintained luminaires have reduced the energy cost difference compared with older emergency lighting products.

New Build vs Retrofit

Installing emergency lighting during construction is usually less costly than retrofitting into an existing occupied building, where containment, cable routes, access restrictions, and disruption to normal operations all affect installation time.

Annual Testing

Annual testing costs are driven by the number of luminaires, the building layout, and the time required to complete the full-duration discharge test. Bell quotes annual testing costs per visit based on the luminaire count confirmed at survey.

A fixed-price installation quote requires a survey to confirm the escape route layout and luminaire positions. Annual testing costs can be quoted from a confirmed luminaire count. Contact Bell to arrange a no-obligation survey.

NSI Gold Accredited · Free Site Survey · No Obligation

Emergency Lighting Legal Requirements in Scotland

Emergency lighting is a legal requirement in most non-domestic premises and in the communal areas of multi-occupied residential buildings. The obligation arises under a combination of fire safety legislation, building regulations, and the relevant British Standard.

Recent Emergency Lighting Articles

A horizontal image showing a neatly mounted LED emergency exit light in a hallway, softly lit. The right side features a navy-blue semi-transparent panel that reads, “How Often Should Emergency Lighting Be Tested?” in clean white text, with ample space in the top-right corner for the Bell Fire & Security logo.

How Often Should Emergency Lighting Be Tested?

Legal Requirements for Emergency Lighting Testing in the UK Key Takeaways: Emergency lighting should be tested monthly. A full-duration test…

Frequently Asked Questions About Emergency Lighting

Emergency lighting is a system of luminaires and exit signs that activates automatically when the mains electrical supply fails, providing illumination of escape routes and exits to allow building occupants to evacuate safely. Every emergency luminaire has its own battery backup that maintains illumination for the required duration — typically one to three hours depending on the building type — independent of the mains supply.

In Scotland, the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 require dutyholders to ensure appropriate fire safety measures are provided and maintained, including emergency lighting where it is needed to support safe evacuation. Scottish Building Standards determine where emergency lighting is required in new and refurbished buildings. BS 5266-1 is the British Standard covering the design, installation, commissioning, testing, and maintenance of emergency lighting systems.

Monthly functional tests are required, confirming every luminaire operates when activated. Annual full-duration discharge tests are required, discharging the battery for the full rated duration (one or three hours) and confirming every luminaire remains operational throughout. Both test results must be recorded in the system log book. Monthly tests are typically carried out by the responsible person in-house. Annual tests must be carried out by a competent person.

Non-maintained luminaires are switched off during normal operation and activate automatically on mains failure. Maintained luminaires are lit continuously, with the battery backup maintaining illumination when mains power is lost. Non-maintained is standard for premises occupied only during daytime hours. Maintained is required in cinemas, theatres, hotels, and anywhere occupied in conditions of low ambient light during normal operation.

BS 5266-1 requires a minimum of one hour for most commercial premises. For sleeping risk buildings — hotels, care homes, residential apartment blocks — the minimum is three hours. Bell specifies three-hour battery systems as a default across all building categories where the standard permits, as they provide more operational headroom and are required for sleeping risk premises.

BS 5266-1 specifies that emergency luminaires must be positioned at every change of direction on an escape route, at every fire alarm call point and fire-fighting equipment location, near every exit sign, at every change in floor level, and at sufficient spacing to achieve the minimum illumination level (1 lux along the centre line) across the full escape route. Exit signs must be positioned at every junction and final exit on the escape route.

BS 5266 is the British Standard series covering emergency lighting. BS 5266-1 covers the code of practice for the design, installation, commissioning, and maintenance of emergency lighting in buildings. It specifies the minimum illumination levels, battery duration requirements, positioning requirements, and testing and maintenance procedures for emergency lighting systems in Scotland and the UK.

Costs depend on the number of luminaires required, the building layout, the system type, and whether the installation is new build or retrofit. A reliable quote requires a survey to confirm the escape route layout and luminaire positions. Annual testing costs can be quoted from a confirmed luminaire count. Contact Bell to arrange a no-obligation site survey.

Our operations are currently focused exclusively within Scotland. At this time, we do not provide services across the wider United Kingdom, though future expansion into additional regions may be considered as part of our ongoing growth strategy.

Related Fire and Security Services

Emergency lighting is one part of a building’s fire safety strategy. Here are the services most commonly combined with emergency lighting installation and maintenance.

■ Fire Alarm Systems

Addressable fire detection and alarm systems provide the trigger for evacuation that emergency lighting is installed to support, with design, installation, and maintenance aligned to the building’s fire strategy.

■ Smoke Detector Installation

Heat and smoke detection across key areas of the building helps ensure occupants receive early warning, beginning the evacuation process that emergency lighting is designed to support.

■ Fire Door Installation

Fire doors help protect escape routes, stairwells, and compartment lines, working alongside emergency lighting to maintain safer evacuation conditions during a fire.

■ Sprinkler Systems

Automatic suppression can provide a complementary active fire safety measure by helping control fire growth and supporting the evacuation strategy that emergency lighting is designed around.

■ Fire Risk Assessment

The starting point for any fire protection programme. A fire risk assessment helps confirm where emergency lighting is required, what duration is needed, and whether existing systems remain suitable for the building.

Keep Your Emergency Lighting Compliant and Operational with Bell

Book a free, no-obligation site survey for a new installation quote or an annual testing enquiry. Our SELECT-accredited engineers will assess your building, confirm the scope of works, and provide a fixed-price quote covering installation or testing — whatever your emergency lighting needs. Whether you have one building or a portfolio of premises, Bell provides the installation, testing, and documentation that keeps your compliance record complete.

Prefer to speak to someone directly?

Call: 0141 883 9000

Email: info@bellfiresecurity.co.uk

We aim to respond to all enquiries within one working day.

Back To Top